About the Facility

The Flow Cytometry Core Facility (FCCF) at Boise State University was created to aid researchers and graduate students in implementing flow cytometry into their experimentation. The facility’s services, housed in the Science building (Room 218), are available primarily to the Boise State University and Treasure Valley communities. The FCCF is equipped with a state of the art four-laser BD INFLUX cell sorter. This instrument supports four-way sorting, plate sorting for single cell isolation, 9-color analysis, and can operate at up to 200,000 events per second. The BD INFLUX at BSU is also equipped with a small particle detector allowing particle detection near 200 nm

Faculty/Staff, Contact InformationDr. Rebecca Hermann

To schedule time or consultation for services, please contact Dr. Hermann.

  • Dr. Denise Wingett – Director, Flow Cytometry Core Facility; Professor, Department of Biological Sciences; Director, Biomolecular Sciences Ph.D. Program; (208) 426-2921; email
  • Dr. Rebecca Hermann, Senior Scientist/Laboratory Manager, Flow Cytometry Core Facility; (208) 426-5940; email


Instrument Capabilities - BD Influx Cell Sorter

LaserEmissionDetectorTypical Flourochromes
488 nm (200 mW)510-550FL-1FITC, GFP, Alexa Fluor 488
565-595*FL-2PE
405 nm (50 mW)435-485FL-3Pacific Blue
525-575FL-4Pacific Orange
355 nm (100 mW)435-485FL-5Hoescht Blue
655-685FL-6Hoescht Red
642 nm (50 mW)655-685FL-7APC
700-740FL-8APC-Alexa Fluor 700
>750FL-9APC-Cy7
*Can substitute PE filter (565-595) with PI filter (600-620) upon request.

Cell Sorting Rates, Policies

Rate 1Rate 2Rate 3
Internal BSU User RatesBD Influx Supplies (flat fee)$30.93$30.93$30.93
BD Influx Cell Sorter (per hour)$17.17$22.12$26.39
External non-BSU federally funded user ratesBD Influx Supplies (flat fee)$43.61$43.61$43.61
BD Influx Cell Sorter (per hour)$24.21$31.19$37.21
Note: Rate 1 based upon usage of 488 laser alone or 640 laser alone or both 488 + 640 lasers together; Rate 2 based upon usage of 488, 640 and 405 lasers; Rate 3 based upon usage of 488, 640, 405 and 355 lasers.

Users will be charged a flat fee for supplies per experiment and charged in ¼ hour increments according to the rates as listed above. Users will be charged time necessary for setup at the appropriate rate (typically ~1 hour dependent on number of lasers, number of markers using, sterility requirements, etc.).

Prior to beginning any cell sorting, investigators must sign the FCCF Registration and Authorization Form.

Applications

There are many uses for flow cytometry, many of which are outlined in this video by Beckman Coulter. Examining, counting, and sorting cells are the primary functions of this technology. Samples are sorted primarily based on the presence of a fluorescent dye, but also size and granularity characteristics. These characteristics assist researchers in the following examples of applications of flow cytometry:

  • Analyze target (Ab bound, fluorescent) versus non-target cellsBD FACSCalibur
  • Measure DNA content of a cell sample
  • Cell cycle analysis determination
  • RNA vs DNA differentiation during cell cycle progression
  • Distinguish between immature and mature RBC
  • Evaluate cell viability
  • Investigate cytokine production from activated cells
  • Monitor second messengers to determine cell activation state
  • Understanding Flow Cytometry

Understanding Flow Cytometry

Flow cytometry analyzes cells based on relative size, granularity, and fluorescence.  A flow cytometer is composed of three main systems: fluidics, optics, and electronics.  The fluidics system operates to inject the cell sample into the sheath fluid for delivery to the laser for interrogation.  Hydrodynamic focusing of the sample within the sheath fluid allows for one cell to pass through the laser at a time.  The optical system contains lasers, lenses, and filters.  As a cell passes through the laser beam it will scatter light for relative size and granularity measurements.  Lasers also excite fluorochromes present in the cell sample.  Lenses and filters are required to direct the scattered and excited light of specific wavelengths to various detectors for collection.  The electronics system converts the light signals received by the detectors to electronic signals using photodetectors (photodiodes and photomultiplier tubes).  These converted light signals are displayed on a graph, such as a dot plot or histogram, that can be used to analyze, gate, or sort a selected cell population in the sample.  Examples of these graphs can be seen here.